Description
Drolet Escape 1500-I Wood Insert With Faceplate - DB03137
Combining performance and respect for the environment, the Escape 1500 is the perfect choice for heating homes up to 1,800 ft². With only 1.26 g/h of particulate emissions, this non-catalytic wood insert gives off up to 65,000 BTU/h while largely meeting EPA standards. The Escape 1500 is the perfect way to update your masonry fireplace, and make it efficient!
Included: 29'' x 44'' faceplate, blower, ceramic glass, ash lip, air damper
FEATURES:
Heating area | 500 - 1,800 Ft2 |
Size | 27 1/4" W X 22 3/8" D X 21 1/4" H |
Maximum log length | 18" |
Average particulate emission rate |
1.26 g/h |
- Burn time up to 6 hours
- Up to 18'' logs
- 1.9 ft³ firebox
- Robust 5/16'' steel
- EPA certified
- Proudly made in Canada
- Limited lifetime warranty
SPECIFICATIONS:
Combustion technology | Non-catalytic |
High-efficiency certified appliance | Yes, EPA 2020 approved |
Maximum log length | 18" |
Log positioning | Loading over width |
Chimney diameter | 6" |
Flue outlet diameter | 6" |
Type of chimney | Liner - ULC-S635, CAN/ULC-S640, UL1777 |
Minimum chimney height (feet) | 12' |
Baffle type | High quality vermiculite |
Approved for a mobile home installation | No |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface – dimensions (Width X Height) | 15 3/4" x 9 3/4" |
Glass air-wash system | Yes |
Premium quality blower included (CFM) | 144 |
Overall dimension (Height) | 21 1/4" |
Overall dimension (Width) | 27 1/4" |
Overall dimension (Depth) | 22 3/8" |
Door opening – dimension (Height) | 8 3/4" |
Door opening - dimension (Width) | 17 1/4" |
Firebox – dimension (Height) | 11 7/8" |
Firebox – dimension (Width) | 19 5/8" |
Firebox – dimension (Depth) | 13 1/2" |
Firebox lined with refractory bricks for better heat distribution | Yes |
Stainless-steel secondary-air system improving gas combustion | Yes |
Adjustable threaded legs | Yes |
Steel thickness – body | 3/16" |
Steel thickness – top | 5/16" |
Fireplace opening – minimum (Height) | 21 1/2" |
Fireplace opening – minimum (Width) | 27 1/2" |
Fireplace opening – minimum (Depth) | 12 3/4" |
USA standard (emissions) | EPA |
Canadian Standard (emissions) | CSA B415.1-10 |
USA standard (safety) | UL 1482, UL 737 |
Canadian standard (safety) | ULC S628 |
Tested and listed as per applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | Limited lifetime |
Fuel type | Dry cordwood (16" recommended) |
Recommended heating area(9) | 500 - 1,800 ft² |
Overall firebox volume | 1.9 ft³ |
EPA loading volume | 1.44 ft³ |
Maximum burn time(9) | 6 h |
Maximum heat output-dry cordwood(4) | 65,000 BTU/h (19 kW) |
Minimum overall heat output rate(4) (5) | 15,650 BTU/h (4.6 kW) |
Maximum overall heat output rate(4) (5) | 23,300 BTU/h (6.83 kW) |
Average overall efficiency-dry cordwood (HHV)(5) (6) | 70 % |
Average overall efficiency-dry cordwood (LHV)(5) (7) | 75 % |
Optimum efficiency(1) (2) | 78 % |
Optimum heat transfer efficiency(8) | 74 % |
Average particulate emission rate(3) | 1.26 g/h |
Average CO(10) | 58 g/h |
Size | Medium |
Premium quality blower included (CFM) | 144 CFM included |
Certified according to applicable standards | By an accredited laboratory (CAN/USA) |
Combustion technology | Non-catalytic |
Stainless-steel secondary-air system | Yes |
Flue outlet diameter | 6" |
Distance-center of the flue outlet to back unit | 5 3/4" |
Distance-center of the flue outlet to side unit | 12 3/4" |
Recommended chimney diameter | 6" |
Type of chimney | Liner - ULC-S635, CAN/ULC-S640, UL1777 |
Minimum chimney height | 12' |
Overall dimension (Width) | 27 1/4" |
(1) This appliance is officially tested and certified by an independent agency.
(2) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(3) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(4) As measured per CSA B415.1-10 stack loss method.
(5) Higher Heating Value of the fuel.
(6) Lower Heating Value of the fuel.
(7) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(8) Optimum overall efficiency at a specific burn rate (LHV).
(9) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(10) Carbon monoxyde.
Clearances:
United-States | |
Clearance – top (measured from the platform on which the appliance is installed)** | 84" |
Clearance – combustible side mantle to unit | 9" |
Clearance – combustible top mantle to unit | 27" |
Clearance – combustible side wall to unit | 16" |
Clearance – minimum floor protection in front of the appliance | 16" |